2.4 Detect of spin defect with bubble
Incase spin rotation (r/min.) has not increased over specified level in the first intermittent spin action of first rinse process, It is judged "Spin defect with bubble".
Thereby, Rinse process has changed to 3 times automatically.
(Please Note: Delicate and Home Dry Care course are excluded)